Technical parameters:
• Current ranges: from 20 A to 400 A DC and from 400 A to 1500 A AC.
• Output sensitivity: 400 A range: 1 mV/A 1500 A range: 0.1 mV/A.
• Accuracy (DC up to 400 Hz): DC range: ± (1.5% of reading + 5) AC range: ± (2.5% of reading + 5).
• Max. operating voltage: 600 V AC rms, category IV.
• Max. jaw opening: 52 mm.
• Max. cable thickness: 50 mm.
• Power On/Low Voltage Indication: If the battery has sufficient charge, the LED illuminates
when the current sensor is turned on and indicates that the power is on. If the LED is not lit, the battery is weak and needs to be replaced.
• Battery: 9V battery, NEDA 1604 or 6F22, 1 piece.
• Degree of protection: IP20.
• Storage temperature: -20°C to 60°C.
• Operating temperature: 0°C to 45°C.
• Altitude: from 0 to 2000 meters.
• Relative humidity: 0% to 80% (at 0°C to 35°C) 0% to 70% (at 35°C to 45°C).
• Dimensions: 248 x 93 x 50 mm (body only).
• Weight: approx. 452 g (with battery).
Compatible with most multimeters.
Automatic zero adjustment, perfectly adapted to FACOM 711, 711A, 714 and 714A multimeters.